ASCO 185 Series Automatic Transfer...

$1,297.20

The ASCO 185 Series automatic transfer switch (ATS) are 2-wire control switches that are compatible with all 2-wire start systems from all manufacturers. The switch monitors incoming utility power. When the utility power fails it starts the generator and transfer the emergency load onto the generator. After the utility power is restored it will transfer the load back to the utility source, cool down the generator and then return to a standby mode. The ATS has an exercise circuit that tests the generator system every week. The automatic test feature can be set under load or under no load.

For information on choosing a Transfer Switch, click here.

Please ensure you read and agree with the return policy:

Printable Brochure:  ASCO 185 Series

 

Asco 185 Series Auto Transfer Switch *

NEMA 3R Enclosure (NEMA 1 Enclosure is standard)

NEMA 3R enclosure provides protection against falling rain, sleet, snow, and external ice formation. Indoors they protect against dripping water.

Strip Heater

A strip heater with thermostat is recommended for extremely cold areas to prevent condensation and freezing of this condensation. An external 120 volt source is required. Part #K732212-003

14A/14B Auxiliary Contacts

Indicate position of main contact. One (1) for normal and one (1) for emergency positions. Part #K373314

Compare

Description

ASCO 185 Series Automatic Transfer Switch

The Series 185 Automatic Transfer Switch incorporates the latest technology developed by ASCO for dependable operation in any environment.

When utility power fails for just 1 second or more, the Series 185 Automatic Transfer Switch signals the generator to start.  In less than 30 seconds your electrical power is normally restored.

Once the Series 185 Automatic Transfer Switch senses utility power has reached an acceptable voltage level for a period of time, it automatically reconnects your utility power. It then smoothly shuts the generator down after an adjustable 2-5 minute cool down period to extend generator life.

The user friendly control panel also allows you to manually run a test at the push of a button.  LED indicators let you know the availability of both power sources and transfer switch positions.

Product Features

  • User friendly control interface with intuitive symbols and visual indicators to inform operator of transfer switch and power source status
  • Listed to UL 1008 for optional standby systems, handling total system load including motors and all other electrical loads
  • cUL Listed for Canadian installations
  • Meets Article 702, NFPA-70 National Electrical Code (NEC) requirements
  • Nominal service voltage 240V 50/60Hz, single phase, 3 wire AC systems
  • Available in 100 through 200 amp ratings
  • 200 Amp Service Entrance designs feature disconnect circuit breaker on normal source
  • True double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility sources
  • Terminals for convenient connection of neutral and ground conductors
  • Available in NEMA 1 indoor (steel) and NEMA 3R outdoor (aluminum) enclosures, with hinged door designs
  • Suitable for controlling standby generators with 2-wire automatic starting circuits

Time Delays:

  • Adjustable 1 or 3 second time delay to override momentary normal source outages to delay all transfer switch and engine starting signals.
  • Transfer to emergency time delay - fixed at 10 seconds.
  • Re-transfer to normal time delay - fixed at 5 minutes.
  • Adjustable 2 or 5 minute unloaded running time delay for emergency engine cool down.
  • Four - second time delay to ignore momentary voltage and frequency transients during initial genset loading.

Type 1  Indoor Enclosure:

  • Listed to UL 50 standard for electrical equipment enclosures.
  • Fabricated from 14 gauge steel.
  • Finish - textured RAL 7035 light gray polyester powder coating
  • Doors secured with captive fasteners.
  • Conduit knockouts on bottom, and both sides.

Type 3R Outdoor Secure Enclosure:

  • Door over door secure construction.
  • Listed to UL 50 standard for electrical equipment enclosures.
  • Fabricated from heavy gauge aluminum alloy suited to the size and ampere rating of the switch.
  • Highly corrosion resistant
  • Finish - textured RAL 7035 light gray polyester powder coating.
  • Doors secured with captive fasteners.
  • Gasketed enclosure minimizes ingress of water and dust.
  • Internal dead front panel for user safety when accessing controls.
  • Conduit knockouts on bottom, and both sides.

Poles:

  • 100 -400 Amp 1-PH - 2 Pole

Actual Dimensions (Inches)(W x H x D):

  • 100 Amp in NEMA 1 Enclosure - 14.25 x 24 x 8.25
  • 200 Amp in NEMA 1 Enclosure - 14.25 x 24 x 8.25
  • 230 Amp in NEMA 1 Enclosure - 14.25 x 24 x 8.25
  • 260 Amp in NEMA 1 Enclosure - 22 x 45 x 7.5
  • 400 Amp in NEMA 1 Enclosure - 22 x 45 x 7.5
  • 100 Amp in NEMA 3R Enclosure - 16 x 24 x 10
  • 200 Amp in NEMA 3R Enclosure - 16 x 24 x 10
  • 230 Amp in NEMA 3R Enclosure - 16 x 24 x 10
  • 260 Amp in NEMA 3R Enclosure - 24 x 48 x 10
  • 400 Amp in NEMA 3R Enclosure - 24 x 48 x 10

Actual Weight (Pounds):

  • 100 Amp in NEMA 1 Enclosure - 44
  • 200 Amp in NEMA 1 Enclosure - 44
  • 230 Amp in NEMA 1 Enclosure - 44
  • 260 Amp in NEMA 1 Enclosure - 79
  • 400 Amp in NEMA 1 Enclosure - 79
  • 100 Amp in NEMA 3R Enclosure - 49
  • 200 Amp in NEMA 3R Enclosure - 49
  • 230 Amp in NEMA 3R Enclosure - 49
  • 260 Amp in NEMA 3R Enclosure - 118
  • 400 Amp in NEMA 3R Enclosure - 118

Shipping Dimensions (Inches)(W x H x D):

  • 100 Amp in NEMA 1 Enclosure - 21 x 31 x 15
  • 200 Amp in NEMA 1 Enclosure - 21 x 31 x 15
  • 230 Amp in NEMA 1 Enclosure - 21 x 31 x 15
  • 260 Amp in NEMA 1 Enclosure - 29 x 52 x 15
  • 400 Amp in NEMA 1 Enclosure - 29 x 52 x 15
  • 100 Amp in NEMA 3R Enclosure - 22 x 31 x 17
  • 200 Amp in NEMA 3R Enclosure - 22 x 31 x 17
  • 230 Amp in NEMA 3R Enclosure - 22 x 31 x 17
  • 260 Amp in NEMA 3R Enclosure - 31 x 55 x 17
  • 400 Amp in NEMA 3R Enclosure - 31 x 55 x 17

Shipping Weight (Pounds):

  • 100 Amp in NEMA 1 Enclosure - 44
  • 200 Amp in NEMA 1 Enclosure - 44
  • 230 Amp in NEMA 1 Enclosure - 44
  • 260 Amp in NEMA 1 Enclosure - 79
  • 400 Amp in NEMA 1 Enclosure - 79
  • 100 Amp in NEMA 3R Enclosure - 49
  • 200 Amp in NEMA 3R Enclosure - 49
  • 230 Amp in NEMA 3R Enclosure - 49
  • 260 Amp in NEMA 3R Enclosure - 118
  • 400 amp in NEMA 3R Enclosure - 118

Optional Accessories:

Strip Heater - A strip heater with thermostat is recommended for extremely cold areas to prevent condensation and freezing of this condensation. An external 120 volt source is required. Part #K732212-003

14A/14B Auxiliary Contacts - Indicate position of main contact.  One (1) for normal and one (1) for emergency positions. Part #K373314